Cable Sizing for Solar PV Systems — PEC 2017 Requirements Explained

Undersized DC cables in solar PV systems are one of the leading causes of residential solar fires in Southeast Asia. The Philippine Electrical Code (PEC) 2017 — aligned with NEC Article 690 — has specific requirements for PV wiring. Most homeowners never check if their installer followed them.

Why DC Cable Sizing Is Different from AC

DC circuits carry continuous current — unlike AC circuits that have natural zero-crossings. PEC 2017 Section 690.8 requires PV source circuit conductors to be sized at 125% of the module's short-circuit current (Isc). Then apply a second 125% factor for continuous load. Combined: cables must handle 156% of rated Isc.

Formula: Cable ampacity ≥ Isc × 1.25 × 1.25 = Isc × 1.5625

Philippine Heat Derating

Cable ratings are based on 30°C ambient temperature. Philippine rooftop cable runs regularly reach 50-60°C, which significantly reduces ampacity.

Ambient TempXLPE Cable Derating FactorEffect on 6mm² cable (47A rated)
30°C (base)1.0047A
40°C0.9142.8A
45°C0.8238.5A
50°C0.7133.4A

Minimum Cable Sizes for Philippine Rooftop Solar

For a typical 5kW system with 550W panels (Isc ≈ 13.9A per string):

What to Ask Your Installer