A "string" is a series connection of solar panels. Each panel's voltage adds up — and if the total string voltage exceeds your inverter's maximum input voltage, you permanently damage the inverter. If it falls below the minimum MPPT voltage, the inverter won't produce power. String sizing is one of the most technically critical steps in solar design.
Panel voltage is not fixed. It changes with temperature — this is described by the temperature coefficient of Voc on the panel datasheet (typically −0.28% to −0.35%/°C). In the Philippines:
| Condition | Temperature | Effect on Voc | Risk |
|---|---|---|---|
| Cold morning (Benguet/Tagaytay) | ~10–15°C | Voc rises ~3–5% | May exceed inverter max V |
| STC (standard test) | 25°C | Nominal Voc | — |
| Hot summer afternoon (Metro Manila) | ~40–50°C | Vmp drops ~7–10% | May fall below MPPT min V |
Using a 550W panel with Voc = 41.5V, Vmp = 34.6V, Tc = −0.30%/°C, and a Deye 5kW inverter (max 500V input, min MPPT 80V):
| Limit | Formula | Result |
|---|---|---|
| Max panels (cold limit) | 500V ÷ (41.5V × (1 + (−0.30/100) × (15−25))) | 500 ÷ 42.7V = 11 panels max |
| Min panels (hot limit) | 80V ÷ (34.6V × (1 + (−0.30/100) × (45−25))) | 80 ÷ 32.5V = 3 panels min |
| Safe string range | — | 3 to 11 panels per string |
Engr. Jason Morales — Founder, SolarEnergyPH